Tubular style linear motors, for extremely high dynamic applications, speeds up to 7.3m/s, acceleration up to 780m/s2, short positioning time and high frequency operations
Speeds of up to 7.3 m/s and accelerations of over 780 m/s2 allow very short positioning times and high cycle rates
LinMot motors are electromagnetic direct drives in tubular form. The linear motion is produced purely electrically and wear-free, without any intermediate coupling of mechanical gearboxes, spindles, or belts. The linear motor consists of just two parts: the slider and the stator. The slider is made of neodymium magnets that are mounted in a high-precision stainless steel tube. The stator contains the motor windings, bearings for the slider, position capture sensors, and a microprocessor circuit for monitoring the motor.
The internal position sensor measures and monitors the current position of the linear motor not only when it is stopped, but also during the motion. Deviations in position are detected immediately and reported to the upper-level controller. LinMot linear motors can be positioned freely within the entire range of the stroke. In addition, both the travel speed and the acceleration can be controlled precisely. For more complex motions, arbitrary travel profiles can be saved as curves in the servo drive and executed by the motor at the desired speed.
Standard Linear Motors
The standard variant of the linear motor can be used universally, covering a wide range of applications. Many different positioning tasks in the low-voltage range can be performed using the compact drives. The family of motors includes 3 models with various lengths of the stator and the stroke. The user can select a maximum stroke length of 1830 mm and peak force of 1024 N. Because the motor components are encapsulated, the motor is optimally protected, even for intensive applications.
• Highly dynamic drives
• Wide range of stroke lengths
• Available with cable outlet or pivoting angled plug
• Air cooling available as an option
• Wide variety of potential applications in handling systems and in machine and systems design
Standard Linear Motors, installation guide
LinMot product overview
Series | Force cont. (N) | Force cont. fan cooling (N) | Force peak (N) | Speed máx. (N) | Stroke máx. (mm) | Variant |
---|---|---|---|---|---|---|
P01-23x80 | 9 | 16 | 44 | 6.0 | 780 | |
P01-23x160 | 17 | 32 | 65 | 3.0 | 780 | |
P01-23x160F | 17 | 32 | 86 | 4.6 | 780 | |
P01-37x120 | 30 | 54 | 163 | 3.2 | 1480 | |
P01-37x120/U | 32 | 59 | 177 | 3.0 | 660 | HiClear |
P01-37x240 | 54 | 100 | 231 | 1.6 | 1480 | |
P01-37x240/U | 59 | 108 | 230 | 1.5 | 660 | HiClear |
P01-37x240F | 54 | 100 | 310 | 2.6 | 1480 | |
P01-37x240F/U | 59 | 109 | 335 | 2.4 | 660 | HiClear |
P01-48x240 | 148 | 259 | 585 | 1.7 | 1830 | |
P01-48x240/U | 128 | 225 | 507 | 2.0 | 750 | HiClear |
P01-48x240F | 148 | 256 | 572 | 3.0 | 1830 | |
P01-48x240F/U | 129 | 222 | 496 | 3.5 | 750 | HiClear |
P01-48x360F | 208 | 360 | 1020 | 2.1 | 1710 | |
P01-48x360F/U | 180 | 312 | 888 | 2.4 | 630 | HiClear |
HP Linear Motors
The High Performance line of linear motors have significantly greater performance than standard motors with the same component size and identical dimensions. This is largely due to the ongoing development of the motor windings and the magnetic circuit, and the use of high-performance materials.
With High Performance motors, the user has access to nearly double the nominal performance. The higher performance in the same form factor allows power to be increased in existing machines and systems without the trouble of mechanical redesign.
• Particularly strong magnetic circuit
• Increased continuous force and acceleration
• Allows higher operating temperatures
• Optimal for applications with limited component mass
HP Linear Motors, installation guide
LinMot product overview
Series | Force cont. (N) | Force cont. fan cooling (N) | Force peak (N) | Speed. max. (m/s) | Stroke max. (mm) | Variant |
---|---|---|---|---|---|---|
P01-23x80F-HP | 15 | 25 | 67 | 7.4 | 780 | |
P01-23x160H-HP | 32 | 48 | 138 | 5.3 | 780 | |
P01-37x120F-HP | 51 | 92 | 255 | 3.9 | 1480 | |
P01-37x120F-HP/U | 42 | 75 | 210 | 4.7 | 660 | HiClear |
Short Linear Motors
This type of motor is the shortest form factor for LinMot linear motors. Short motors have been developed especially for applications with limited space constraints. The short form factor also means that multi-axis applications can be implemented with several stators on one slider in a very small space. In order to provide the designer with as many options as possible for cable routing, these motors are provided with three covers for the cable outlet on the left, the right, or the front side. The motor cable can be plugged in under the cover for quick and easy installation.
• Short form factor with a minimum stator length of 90 mm
• Integrated mounting flange
• Plug-in motor cable with cover
• Selectable cable outlet position
• For use with limited space constraints and multi-axis applications
Short Linear Motors, installation guide
LinMot product overview
Series | Force cont. (N) | Force cont. fan cooling (N) | Force peak (N) | Speed. max. (m/s) | Stroke max. (mm) | Variant |
---|---|---|---|---|---|---|
P02-23Sx80 | 9 | 16 | 44 | 6.0 | 780 | |
P02-23Sx80F-HP | 14 | 25 | 67 | 7.4 | 780 | |
P01-37Sx60-HP | 17 | 34 | 128 | 4.9 | 1480 | |
P01-37Sx60-HP/U | 14 | 28 | 105 | 6.0 | 660 | HiClear |
P01-37Sx120F-HP | 37 | 70 | 255 | 3.9 | 1480 | |
P01-37Sx120F-HP/U | 30 | 58 | 210 | 4.7 | 660 | HiClear |
Linear Motors 3x400Vac medium power
The P10-54 motors are available in 4 sizes, with forces ranging from 350 to 900 N. The extensive selection of sliders produces a closely tiered range of strokes, with a maximum stroke of up to 2000 mm. The motor data, with accelerations from 400 m/s2 and a maximum speed of over 10 m/s, leave nothing to be desired in terms of dynamics. The rotating TWIN plug with push-pull connectors for power and encoder cables provides the greatest possible flexibility in the cable exit, guaranteeing reliable, time-saving cable routing in the system. The single-piece clamping flange supports fast and easy installation of the stator in the system.
Optionally equipped with a 1Vpp sin/cos encoder or an A/B incremental encoder, the P10-54 linear motors can be controlled by any manufacturer‘s drives. This makes them easy to integrate into an existing controls concept, using the drives that the machine or systems supplier has selected. Alternatively, the linear motors can be controlled by LinMot series C1400 drives for 230VAC or E1400 drives for 3x400VAC.
• 230Vac and 3 x 400Vac technology
• Peak force up to 900 N
• Extremely high accelerations and speeds
• Rotating push-pull TWIN connectors for sensor and power cables
• Operation with commonly available servo controllers
Series | Force cont. (N) | Force cont. fan cooling (N) | Force peak (N) | Speed max. (m/s) | Stroke max. (mm) |
---|---|---|---|---|---|
P10-54x120U | 70 | 102 | 357 | 8.5 | 2240 |
P10-54x180U | 105 | 153 | 535 | 11.1 | 2180 |
P10-54x240U | 140 | 204 | 714 | 8.4 | 2120 |
P10-54x300U | 175 | 255 | 892 | 8.7 | 2060 |
Linear Motors 3x400Vac high power
The P10-70 series of motors are the most powerful drives that LinMot makes.
The larger motors with increased performance and more than three times the peak force present greater challenges for drive units and servo drives. Therefore, LinMot has developed an entirely new concept here, with a three-phase winding and servo drives that are fed directly from the grid.
The control electronics and the motor together provide an outstanding alternative to conventional design elements.
Series P10-70 linear motors are available with various encoder interfaces and can therefore be controlled by third-party servo drives without any difficulties. Series P10-70 linear motors have been tested together with the leading manufacturers of servo drives.
• 3 x 400Vac technology
• Peak force up to 2700 N
• Extremely high accelerations and speeds
• Separate plugs for sensor and power cables
• Operation with commonly available servo controllers
Linear Motors 3x400Vac high power, installation guide
LinMot product overview
Series | Force cont. (N) | Force cont. fan cooling (N) | Force cont. fluid cooling (N) | Force peak (N) | Speed max. (m/s) | Stroke max. (mm) |
---|---|---|---|---|---|---|
P10-70x80U | 70 | 107 | 188 | 561 | 6.1 | 1770 |
P10-70x160U | 137 | 209 | 368 | 1120 | 5.6 | 1690 |
P10-70x240U | 202 | 306 | 536 | 1650 | 5.3 | 1610 |
P10-70x320U | 271 | 413 | 728 | 2180 | 4.9 | 1530 |
P10-70x400U | 338 | 519 | 933 | 2720 | 3.9 | 1450 |